Aller au contenu

lesourd2

Membres
  • Compteur de contenus

    543
  • Inscription

  • Dernière visite

Tout ce qui a été posté par lesourd2

  1. lesourd2

    Echelle

    Salut Ou alors ceci au choix : (defun c:ecb(/ pos js blk blk2 ins nblk lis myecho) (princ "\nDeveloppe par AMATI Ph. (Novembre 2002) (Ver:1.0)") (setq myecho (getvar "cmdecho")) (setvar "cmdecho" 0) (setq pos 0) (setq fe (getreal "\nFacteur d'echelle : ")) (initget 128 "Unique Global") (setq nblk (entsel "\n Choix du bloc : ")) (cond ((= nblk "Unique") (setq nblk (entget (car (entsel "\nChoix du bloc :")))) (while (/= (cdr (assoc 0 nblk)) "INSERT") (setq nblk (entget (car (entsel "\nChoix du bloc :")))) ) (setq blk (cdr (assoc -1 nblk))) (setq ins (cdr (assoc 10 nblk))) (command "_scale" blk "" ins fe) ) ((/= nblk "Unique") (if (= nblk "Global") (setq nblk (entsel "\nChoix du bloc :")) ) (setq nblk (entget (car nblk))) (while (/= (cdr (assoc 0 nblk)) "INSERT") (setq nblk (entget (car (entsel "\nChoix du bloc :")))) ) (setq nblk (cdr (assoc 2 nblk))) (setq lis (list (cons 0 "INSERT") (cons 2 nblk))) (setq js (ssget "X" lis)) (if js (progn (while (ssname js pos) (setq blk (ssname js pos)) (setq blk2 (entget (ssname js pos))) (setq ins (cdr (assoc 10 blk2))) (command "_scale" blk "" ins fe) (setq pos (+ pos 1)) ) ) ) ) ) (setvar "cmdecho" myecho) (princ) ) Te permet de changer l'echelle sans changer le point d'insertion. Merci a son auteur. @+ [Edité le 31/10/2008 par lesourd2]
  2. Salut, et bienvenu. Penses tu a bien enregistrer une fois tes modifs effectuées sur tes fichiers ? En revenant sur ton fichier (SORTIE), AutoCAD t'avertit qu'un fichier a ete modifie et t'invites a le rechaerger. @+
  3. lesourd2

    Je sais pas

    Salut Non ABS = Autodesk Building Systems De plus Autodesk a creer des espaces de travail specifique à chaque discipline: 1) HVAC (CVC) 2) Tuyauterie 3) Equipement electrique 4)Plomberie 5)Schematique 6) Architecture Et à chaque espace de travail des palettes d'outils specifiques [Edité le 28/10/2008 par lesourd2]
  4. Salut une petite video explicative . @+
  5. lesourd2

    Je sais pas

    Salut La conception d'AutoCAD MEP repose et est basee sur l'application AutoCAD .avec en plus des fonctions de trois grandes disciplines. Mecanique Electricite Plomberie @+
  6. Salut Merci de ton aide "positive" lili2006.
  7. lesourd2

    X ref

    Salut menu INSERTION => reference dwg => choisir le fichier à inserer => cliquer sur le fichier. Selon que ton point d'insertion est defini ou pas coches ou decoches la case point d'insertion. Sinon par defaut le point d'insertion est ,0,0,0. http://images.imagehotel.net/vs1o2f3pu9.jpg. @+
  8. Salut Tente une restauration ou reinitialisation http://images.imagehotel.net/lqnyo4h2z7.jpg Sinon une reparation ou une reinstallation à partir de ton CD. BON COURAGE @+
  9. Salut Essaies par le menu comme ci-dessus Si ça passe pas c'est que tes express sont mal installes. @+ http://images.imagehotel.net/joubq51h6o.jpg
  10. Salut LILI 2006 avait fait un post sur la migration des fichiers de personnalisation de version anterieures vers 2008. En cherchant sur le site : rien, ou alors je m'y prends mal. Si quelqu'un pouvait me rafraichir la memoire Merc par avance
  11. lesourd2

    Recherche gentopo.lsp

    Salut a voir une piste ici. @+
  12. Salut peute-etre EDIT BLOC de Gile . @+
  13. lesourd2

    SPRINKCAD

    Salut à tous J'aimerais bien avoir votre avis sur ce logicilel (avantages ; inconvenients...). Est-il le plus adapte pour les installations de type SPRINKLER ? Quelles sont ces fonctionnalites, est -il possible de calculer les pertes en charges. Existe t-il un autre logicilel parfaitement adapté au SPRINKLER. J'attends avec impatience les reflexions des gens du metier et meme des autres "qui savent" @+
  14. lesourd2

    menu expresse super hache

    Salut Tant mieux au plaisir sur ce site @+
  15. Salut Essaies ceci (trouvé sur ce site) ;************************************************************************** *************************************************************************** ***** ;;; DEL_BLK.LSP ;************************************************************************* *************************************************************************** ****** ;Supprime les superpositions de blocs (même nom, même calque, même point d'insertion, même rotation, mêmes échelles) (defun c:deldup_blk (/ ss ssdup ct len e eb pt lay bname ang sclx scly sclz obj obj_list ) (princ "\nSelect block objects.") ;Select objects and filter all but block insert objects. (setq ss (ssget (list (cons 0 "INSERT")))) (if ss ;If any valid objects were selected. (progn (princ "\nBuilding list of objects.") (setq ssdup (ssadd)) ;Initialize new selection set to hold objects to delete (setq len (sslength ss)) ;Find out how many objects were selected. (setq ct 0) (while (< ct len) ;Loop through selected objects (setq e (ssname ss ct)) ;Get an object name (setq eb (entget e)) ;Get the entity list from the object name (setq ct (+ ct 1)) ;Increment index into selection set (setq pt (cdr (assoc 10 eb))) ;Access object's coordinate (setq lay (cdr (assoc 8 eb))) ;Access object's layer (setq bname (cdr (assoc 2 eb))) ;Access object's block name (setq ang (cdr (assoc 50 eb))) ;Access object's rotation angle (setq sclx (cdr (assoc 41 eb))) ;Access object's x scale (setq scly (cdr (assoc 42 eb))) ;Access object's y scale (setq sclz (cdr (assoc 43 eb))) ;Access object's z scale ;Make list of object properties (setq obj (list pt lay bname ang sclx scly sclz)) (if (not (member obj obj_list)) ;If these properties are not already in list (setq obj_list (cons obj obj_list)) ;Add them to the list (ssadd e ssdup) ;Else add object to selection set to delete ) ;End if ) ;End of while loop (if (> (sslength ssdup) 0) ;If there are any objects in the selection set to delete (progn (princ "\nDeleting duplicate objects.") (setq len (sslength ssdup)) ;Find out how many many objects to delete. (setq ct 0) (while (< ct len) ;Loop through objects and delete. (setq e (ssname ssdup ct)) ;Get object name (setq ct (+ ct 1)) ;Increment index into selection set (entdel e) ;Delete duplicate object ) ;End of while loop (princ ;Print the number of objects deleted to command line (strcat "\nDeleted " (itoa len) " duplicate objects." ) ;_ Fin de strcat ) ;_ Fin de princ ) ;End progn (princ "\nNo duplicates found.") ;Else no there were no duplicates to delete. ) ;End if ) ;End progn (princ "\nNo block objects selected.") ;Else there were no valid objects selected ) ;End if (princ) ) ;_ Fin de defun (prompt "\ndeldup_blk : Supprimer les superpositions de blocs" ) ;_ Fin de prompt. @+ [Edité le 26/9/2008 par lesourd2]
  16. Salut Bienvenu Pour changer X fois le meme attribut d'un bloc => commande GATTE. @+
  17. lesourd2

    menu expresse super hache

    Salut Commande: _imageframe Entrez le paramètre du cadre de l'image [0, 1, 2] <1>: 0. La valeur 2 = visible à l'ecran invisble à l'impression @+ [Edité le 25/9/2008 par lesourd2]
  18. lesourd2

    perte des menus

    Salut Essayes de réinitialiser le profil par défaut "profil sans nom" . Ou essayes d'importer un de tes profils. @+
  19. Salut As tu des images dans tes fenetres?
  20. Salut Regarde la variable : LAYOUTREGENCTL De preference =2 @+
  21. Salut Et voila comment d'un fichier tres lent a ouvrir on finit par faire les caves. @+
  22. Salut commande : CONVERTCTB. A la limite ce n'est meme pas une question d'interet, ça depend du metier partiqué. Moi c'est pareil dans mon corps d'etat je ne l'utilise pas parce que pas besoin tout simplement. Chaque metier utilisera de maniere differente AutoCAD .
  23. Salut . Ben oui tu te trompes le vins de la Loire t'en fais quoi !! et en particulier les vins de Touraine m'enfin !. . Pour moi là c'est toutes categories
  24. Salut Oui il existe une norme, en fait c'est une reglementation : ARRETE DU 31/01/1986 realtif à la protection des batiments d'habitations contre l'incendie . Toi normalement tu fais partie de la "1ere famille"; a savoir: HABITATIONS INDIVIDUELLES ISOLEES OU JUMELEES A 1 ETAGE SUR RDC AU PLUS. Je te cite l'article et tu me dis ce que tu en penses A savoir aussi que cette prescription ne s'applique pas aux planchers bas au dessus d'un vide sanitaire non accessible. Bref pour moi aucun degre coupe-feu a appliquer au regard de la reglementation si ce n'est que celui du materiau employé là en l'occurence le polystyrene. @+
  25. lesourd2

    BCOUNT dépoussiéré

    Salut (gile) testé sans probleme Merci .
×
×
  • Créer...

Information importante

Nous avons placé des cookies sur votre appareil pour aider à améliorer ce site. Vous pouvez choisir d’ajuster vos paramètres de cookie, sinon nous supposerons que vous êtes d’accord pour continuer. Politique de confidentialité