TBX AES 400
|
|||
---|---|---|---|
Supply voltage +SV
|
19,2 to 60 V
|
||
Nominal voltage +SV
|
24 V
|
48 V
|
|
Current drawn at +SV by the AES used as a basic module (1)
|
130 mA typically
190 mA max.
|
75 mA typically
105 mA max.
|
|
Additional current drawn from a basic module when the AES module is used as an extension
|
negligible
|
||
Current drawn at +SV by the AES used as an extension
|
130 mA typically
190 mA max.
|
75 mA typically
105 mA max.
|
|
Isolation
|
between channels
|
500 V rms - 50/60 Hz for 1 min
|
|
between channels and ground (GND)
|
500 V rms - 50/60 Hz for 1 min
|
||
between channel and supply
|
1500 V rms - 50/60 Hz for 1 min
|
||
between ground and supply
|
1500 V rms - 50/60 Hz for 1 min
|
||
Permissible common mode voltage between channel and ground and between channels during operation
|
+ or - 100 V continuous or 75 Vrms.
|
||
Key:
|
|||
(1)
|
In terms of consumption, do not forget to consider the current drawn at +SV by the TBX LEP 030 communication module from the basic module.
|