At a Glance

This configuration section, accessible from Tools > Options > General , contains a set of general options.

General Options Dialog Box

Representation of the General section:

Description

Elements of the General section:

Fields

Description

General

Auto incrementation of project version

When this option is selected, the project version is automatically incremented on each build.

Auto completion of the variable name

This option is useful when you start the data selection to enter the name of a variable: for example, a pin of a block in FBD.

When it is selected, you can enter the first characters of a variable to select one of these that matches with the entered string. If the entered string has been already used before, the auto completion feature completes the string with the last variable that was used.

Display errors / messages

If Message box is selected, all detected error messages are displayed in dialog boxes.

If Output window is selected, all detected error messages are displayed in the output window.

Contextual Restore at project opening

If this box is selected, the windows have the same arrangement whereas the project is opened or closed. A .ZTX file is generated, which saves the context.

Display list of modified sections before build

When this box is checked, the modified sections are listed in the List of modified sections dialog box after activating the Build Changes command in the Build menu.

General > Paths

Project path

Path where the .STU project files are saved or from where they are retrieved when opening.

Import/Export file path

Path where the import/export source files are kept: for example, .XEF files.

XVM path

Path where the .XVM file is stored.

This file is automatically generated to back up the variables of the project every time this one is transferred to the PLC.

The default path is the same as the default Project path.

Project settings templates path

Path where the Project Settings templates are located.

Project settings template file

Project settings template file that is proposed in the Settings File during the New Project creation.

Custom Library path

Path where the custom libraries are located. Changing the custom library path is taken into account at next open project or new project.

Working drive

Workspace used by the software.

Log files path

Path where the workspace is used by the software.

NOTE: The libraries provided by Schneider Electric are located in a Control Expert system folder. You cannot change the location of these libraries.

To use a previously created custom library after changing the Custom Library Path , move the library file to the new location.