This bit (status 1) indicates that the
Reference point function has been correctly executed.
Applied to Real Axis Function
The axis position reading is referenced from the source.
This bit is not set to 1 in the following cases:
-
the reference point function has never been executed or failed to complete,
-
the SERCOS® network breaks down or the drive detects a failure in the position feedback device,
-
following the
Unhome function.
NOTE: This bit is set to 1 following the
ForcedHomed function.
Applied to Imaginary Axis Function
Not significant.
Applied to the Group of Co-ordinated Axes, Group of Slave Axes or SERCOS® Ring Functions
This bit is set to 1 if one or more member axis AXIS_HOMED bits (AXIS_IS_LINKED) are set to 1.