This bit (status 1) indicates a modification to a class 2 SERCOS® diagnostic bit.
The IDN 0012 variable contains current information.
This bit is set to 0 when reading the IDN 0012 variable.
Applied to Real Axis Function
A class 2 diagnostic bit has changed (Warning).
Applied to Imaginary Axis Function
Not significant
Applied to the Group of Co-ordinated Axes, Group of Slave Axes or SERCOS® Ring Functions
This bit is set to 1 if one or more member axis DRIVE_WARNING bits (AXIS_IS_LINKED) are set to 1.