To configure the communication channel, you must complete the parameters specific to the project.
These are made up of two windows:
The window is set out as follows:
The Handling on stopped mode zone allows you to define the strategy to be applied to outputs and message handling when the project is in Stop mode:
-
PMS: selects the behavior of the PMS services,
-
Inactive: default value,
-
Active.
-
Outputs: selects the output fallback mode,
-
Maintain: the value of the outputs is maintained,
-
Fallback: the outputs revert to their original values.
The
Nbr IW/QW field allows the
number of words used for the inputs/outputs to be selected: 128 or 242.
INTERBUS configuration file
The window is set out as follows:
The Auto box allows automatic selection of the bus configuration mode:
-
This mode is automatically triggered by powering up the INTERBUS bus,
-
It allows rapid verification, without using the CMD Tool software, of the installation’s wiring without any handling or testing,
-
The PCP channels are limited to 64 bytes.
The Control Expert->IBY box is used to select the bus configuration mode via Control Expert:
-
This mode requires the use of CMD Tool in order to generate a *.SVC configuration text file and to import it into Control Expert,
-
The
Select button is used to retrieve this file or any other existing
*.SVC text file,
This file describes the behavior of the application and all the configuration information to be sent to the module before the field bus is started up,
-
The adjoining screen displays the file used for the bus configuration.
-
INTERBUS can be started from downloading in the module and configuration monitoring (secured mode),
-
This mode allows access to advanced INTERBUS services (preprocessing, logical addressing, segmentation, etc.),
-
If a TSX IBY 100 /TSX IBX 100 module has to be replaced, the configuration is automatically reloaded into the new module. This process does not require CMD Tool software.
The CMD->IBY box allows you to select the bus configuration mode using the CMD Tool:
-
If the configuration size exceeds 8 Kwords, a third mode, CMD->IBY, allows the configuration to be loaded onto the module,
-
Every intervention on a module linked with INTERBUS requires the use of CMD Tool software.