Electrical Range
|
0 to 25 mV
|
Minimum Dynamic
|
4.5 mV
|
Maximum Dynamic
|
25 mV
|
Converter Resolution
|
24 bits (16,777,216 points)
|
Limitations of Use
|
50 000 pts
|
Conversion Speed
|
45 measurements/second
|
Load Cell Supply Voltage
|
5 V (switched)
|
Load Cell Wiring Distance
|
300 m (with no loss of precision with 4 load cells)
|
Zero Drift
|
< 200 nV/°C
|
Gain Drift
|
< 10 ppm/°C
|
Non Linearity
|
< 20 ppm (FS)
|
50 Hz Series Mode Rejection
|
> 120 dB
|
Maximum Length of the Measurement Cable
|
100 m for cable at 0.4 mm2
200 m for cable at 0.6 mm2
For 1 to 8 sensors
|
Typical
|
Maximum
|
||
---|---|---|---|
Consumption
|
on 5 VDC
|
150 mA
|
330 mA
|
on 24 VR (1)
|
7 mA + 17 mA x N
|
14 mA + 17 mA x N
|
|
Dissipated Power
|
0.75 W
|
1.65 W
|
|
Key:
|
|||
(1)
|