Description of Parameters Adjustable by Program
(Original Document)
Description
The following table describes the parameters that can be adjusted by program, using the WRITE_PARAM instruction.
Word
Role
Description
%MWr.m.0.6
%MWr.m.0.15
%MWr.m.0.16
Filter Coefficients
The admissible filter coefficient values are between 0 and 19.
%MWr.m.0.7
"Manual" tare value
The admissible "manual" tare values are between 0 and 65535. They cannot exceed the maximum range.
%MD r.m.0.8
%MD r.m.0.10
Cut-off points (thresholds)
S0 high flow cut-off point.
S1 low flow cut-off point.
The threshold values allowed lie between 0 and the maximum range in high resolution format..
If a threshold check has not been defined at configuration, no detection processing is done. The value of these threshold is zero by default.
Note:
  • when weighing: GD < MW < Maximum weight
  • in downweighing: MW < GD < Maximum weight
The module carries out a consistency check of the threshold values. If this logic is not respected, the thresholds will be refused.
%MWr.m.0.12
Output logic
  • %MWr.m.0.12.0:
    • 0: Weighing
    • 1: Downweighing
  • %MWr.m.0.12.1:
    • 0: S0 then S1
    • 1: S0 then S1 then S1
%MWr.m.0.13
PD mask time
The admissible values are between 0 and 15 per 1/10 second step (0 = 0 s, 1 = 0.1 s, 2 = 0.2 s, ...).
%MWr.m.0.14
Number of measurements for flow
Admissible values are values 2, 4, 8, 16, 32 or 64.