Weighing Module Configuration Parameters
(Original Document)
Configuration Parameters
The following table shows the parameters available for the weighing module.
Parameters
Possible Choices
Unit of Measurement
Task
Mast/Fast
-
Metrology/Unit
kg
kilogram
g
gram
t
tonne (metric)
lb
pound (= 453 g)
oz
ounce (= 28.35 g)
<none>
-
Metrology / Max Range
from 0 to 65535 (150)
in the weight unit chosen
Metrology / Scale Division
1 x 10n (1 x 10-2 = 0.01)
in the weight unit chosen
2 x 10n
5 x 10n
Metrology / Overload Threshold
+9 e
scale divisions
+2 % PM
% of Max range
+5 % PM
% of Max range
Zero / Zero Tracking
Inactive/active
-
Zero / Extent of Range
+/-2 % PM or +/-5 % PM
-
Data Format
Legal/High resolution
-
Stability / Extent of Range
2, 3, 4, 6 or 8
1/4 of the scale division
Stability / Time
0.4, 0.5, 0.7 or 1
seconds
Filtering / Coefficients
F1
from 0 to 19 (4)
-
F2, F3
from 0 to 19 (0)
-
Flow / Calculation
2, 4, 8, 16, 32 or 64
measurements
Tare
Not predefined/predefined
in the weight unit chosen
Threshold Check
Inactive/Active
-
LF Mask Time
0 to 1.5 s per 0.1 s step
seconds
Output Logic
Weighing/Downweighing
-
Phase 1 Active Outputs
S0 or (S0 and S1)
-
Breaking Points PD and GD
from 0 to Max Range
in 1/100ths of the unit
NOTE: The parameters in bold correspond to the parameters configured by default.