Modification of the Filtering Value for Analog Module Channels
(Original Document)
At a Glance
This parameter defines the type of filtering for the selected input channel of analog modules.
The available filtering values are:
NOTE: If the fast scan cycle is selected, filtering is not taken into account.
Procedure
The following table shows the procedure for defining the filtering value assigned to the analog module inputs.
Step
Action
1
Access the hardware configuration screen of the required module.
2
Click, for each input channel required, on the arrow of the drop-down menu in the Filter column.
3
Result: The drop-down menu appears:
4
Select the filtering value to assign to the selected channel.
5