LEDs
|
The simulated CPU is in state...
|
Meaning
|
||||
---|---|---|---|---|---|---|
RUN
|
ERR
|
SRUN
|
S
|
M
|
||
–
|
–
|
–
|
–
|
–
|
NOCONF
|
The LED display is replaced with NOCONF - INVALID display.
No user project loaded or the loaded project is invalid.
|
flashing
|
off
|
on: SAFE task running
off: SAFE task stopped.
|
on: Safety mode
|
off
|
STOP
|
The project loaded on the PLC has not been started or has been reset with the Reset button.
|
off
|
flashing: Maintenance mode
|
|||||
on
|
off
|
on: SAFE task running
off: SAFE task stopped.
|
on: Safety mode
|
off
|
RUN
|
A project with at least one task is running.
|
off
|
flashing: Maintenance mode
|
|||||
flashing
|
flashing
|
on: SAFE task running
off: SAFE task stopped.
|
on: Safety mode
|
off
|
HALT
|
A detected error has occurred in the project. The simulated CPU must be reinitialized or reset using the Reset button.
|
off
|
flashing: Maintenance mode
|
|||||
off
|
on
|
off
|
off
|
off
|
SAFE
|
An unrecoverable detected error has occurred in the project. This means communication is no longer possible. The simulated CPU must be reset using the Reset button.
|