I/O Devices
Original instructions
Introduction
This topic lists the Quantum and Modicon X80 I/O devices that can be connected to an Ethernet remote I/O network.
To add I/O modules to an Ethernet remote I/O drop in Control Expert offline mode, click and drag the modules from the Hardware Catalog to the remote I/O drop in the bus editor. You can also double-click the rack slot in which you want to insert the I/O module and select from the New Device dialog box. The available I/O modules are listed in the following tables.
Quantum Analog and Digital Modules
These analog and digital I/O modules are supported in Quantum Ethernet remote I/O drops:
Input
Output
Input/Output
Analog I/O Modules:
140 ACI 030 00
140 ACO 020 00
140 AMM 090 00
140 ACI 040 00
140 ACO 130 00
140 AII 330 00
140 AIO 330 00
140 AII 330 10
140 AVO 020 00
140 ARI 030 10
140 ATI 030 00
140 AVI 030 00
Digital I/O Modules:
140 DDI 153 10
140 DDO 153 10
140 DDM 390 00
140 DDI 353 00
140 DDO 353 00
140 DDM 690 00
140 DDI 353 10
140 DDO 353 01
140 DAM 590 00
140 DDI 364 00
140 DDO 353 10
140 DDI 673 00
140 DDO 364 00
140 DDI 841 00
140 DDO 843 00
140 DDI 853 00
140 DDO 885 00
140 DAI 340 00
140 DAO 840 00
140 DAI 353 00
140 DAO 840 10
140 DAI 440 00
140 DAO 842 10
140 DAI 453 00
140 DAO 842 20
140 DAI 540 00
140 DAO 853 00
140 DAI 543 00
140 DRA 840 00
140 DAI 553 00
140 DRC 830 00
140 DAI 740 00
140 DVO 853 00
140 DAI 753 00
140 DIO 330 00
140 DII 330 00
140 DSI 353 00
Modicon X80 Analog and Digital Modules
These analog and digital I/O modules are supported in Modicon X80 Ethernet remote I/O drops:
Input
Output
Input/Output
Analog I/O Modules:
BMX ART 0414
BMX AMO 0210
BMX AMM 0600
BMX ART 0814
BMX AMO 0410
BMX AMI 0410
BMX AMO 0802
BMX AMI 0800
BMX AMI 0810
Digital I/O Modules:
BMX DDI 1602
BMX DDO 3202K
BMX DDM 16022
BMX DDI 1603
BMX DDO 6402K
BMX DDM 16025
BMX DDI 1604
BMX DDO 1602
BMX DDM 3202K
BMX DAI 0805
BMX DDO 1612
BMX DAI 0814
BMX DAO 1605
BMX DAI 1602
BMX DAO 1615
BMX DAI 1603
BMX DRA 0804
BMX DAI 1604
BMX DRA 0805
BMX DAI 1614
BMX DRA 0815
BMX DAI 1615
BMX DRA 1605
BMX DDI 3202K
BMX DRC 0805
BMX DDI 6402K
NOTE: Schneider Electric recommends that you upgrade the module with the latest available software version. However, a BMX ART 0414 module, V2.1 or later, can work properly behind a Modicon X80 remote I/O adapter module.
Intelligent and Special Purpose Modules
These intelligent/special purpose modules are supported in Quantum and Modicon X80 Ethernet remote I/O drops:
Type
Quantum Module
Modicon X80 Module
BMX CRA 312 00
BMX CRA 312 10
expert
140 ERT 854 10
BMX ERT 1604T
140 ERT 854 20
140 ESI 062 10
counting
140 EHC 105 00
BMX EHC 0200
140 EHC 202 00
BMX EHC 0800
communication
140 XBE 100 00
BMX NOM 0200.
Restrictions are described in chapter BMXNOM0200 Limitation and Implementation Rules.
BMX EIA 100 (max of 1 per drop; may be combined with one BMX NOM 0200 module)
fiber cable conversion
140 NRP 312 00/01
BMX NRP 0200/01
NOTE: Schneider Electric recommends that you upgrade the module with the latest available software version. However, a BMX NOM 0200 module, V1.4 or later, can work properly behind a Modicon X80 remote I/O adapter module.
Modicon X80 Analog and Digital Module Versions
When the following modules are used in an EIO drop with a BMX CRA 312 10 adapter module, they require these versions (or later):
Module
Product Version
Hardware Release Level
Software Version
BMX AMI 0410
PV5
RL5
SV1.1
BMX AMM 0600
PV5 (PV6)
RL5 (RL6)
SV1.2
BMX AMO 0210
PV7 (PV8)
RL7 (RL8)
SV1.1
BMX ART 0414
PV5 (PV6)
RL5 (RL6)
SV2.0
PV7
RL7
SV2.1
BMX ART 0814
PV3 (PV4)
RL3 (RL4)
SV2.0
PV5 (PV6)
RL5 (RL6)
SV2.1
BMX EHC 0200
PV3
RL3
SV1.1
BMX EHC 0800
PV3
RL3
SV1.1