Object
|
Type
|
Symbol
|
Detail
|
---|---|---|---|
%MDr.m.c.14
|
DINT
|
SW_High_Limit
|
Software Pulse Number High Limit
Value from -2,147,483,647 to 2,147,483,647
Default: 2,147,483,647
|
%MDr.m.c.16
|
DINT
|
SW_Low_Limit
|
Software Pulse Number Low LimitValue from -2,147,483,648 to 2,147,483,646
Default: -2,147,483,648
|
%MWr.m.c.18
|
UINT
|
Start_Freq
|
0: No use of start frequency parameter (Default)
Otherwise: value in Hz from 1 to 65,535
|
%MWr.m.c.19
|
UINT
|
Stop_Freq
|
No use of stop frequency parameter (Default)
Otherwise: value in Hz from 1 to 65,535
|
%MWr.m.c.20
|
UINT
|
Acc_Rate
|
For all profiles except Frequency Generator
Value from 10 to 32,500
Default: 100
|
%MWr.m.c.21
|
UINT
|
Dec_Rate
|
For all profiles except Frequency Generator
Value from 10 to 32,500
Default: 100
|
%MWr.m.c.22
|
UINT
|
Emergency_Dec_Rate
|
Deceleration rate used in case of emergency stop (limits crossed, errors)
Value from 10 to 32,500
Default: 100
|
%MWr.m.c.23
|
UINT
|
Homing_Velocity
|
For Homing Command:
Value in Hz from 1 to 65,535
Default: 1
|
%MWr.m.c.24
|
UINT
|
Homing Time Out Value
|
For Homing Command:
Only used when Homing I/O Settings parameter is set to 2.
Value in ms from 0 to 65,535
Default: 65,535
|
%MWr.m.c.25
|
INT
|
Hysteresis (slack)
|
When Output mode is A/B Phases (reversed or not):
Defines the numerical hysteresis to apply on PTO outputs in case of change of direction
Value in pulses from 0 to 255
Default: 0
|
%MWr.m.c.26
|
INT
|
Reserved
|
Reserved
|