Accessing the recipe adjustment parameters for the module
(Original Document)
Role
This operation is used to access the recipe adjustment parameters for the TSX CCY 1128 module.
Adjust Recipe mode provides access to all the recipe parameters.
Confirming modifications online causes the cam function to stop (Cam processor to Stop). Adjust mode can be used to access certain parameters (values in blue in the associated fields) without stopping the cam processor.
NOTE: The values are updated when the window is opened.
Preliminary conditions
The TSX CCY 1128 module must already be configured.
Procedure
The following table describes the operations to be performed:
Step
Action
1
Access the configuration screen of the module.
2
Select the Adjust tab.
3
Confirm the configuration entered if the confirmation request dialog box is displayed.
4
In the browser, click on the recipe element to be entered:
  • Parts counter
  • Connector 0 or 1