Quantum EFB SY/MAX Specific Error Codes
Original instructions
SY/MAX-Specific Error Codes
When using SY/MAX Ethernet, three additional types of errors may appear in the CONTROL[1] register of the control block.
The error codes have the following meaning:
SY/MAX-Specific Hexadecimal Error Codes
SY/MAX-specific hexadecimal error codes:
Hex. Error Code
Description
7101
Invalid opcode found by the SY/MAX remote device
7103
Invalid address found by the SY/MAX remote device
7109
Attempt to write to a write protected register found by the SY/MAX remote device
F710
Receiver overflow found by the SY/MAX remote device
7110
Invalid length found by the SY/MAX remote device
7111
Remote device not active, no connection (occurs when retry attempts and time-out have been used up), found by the SY/MAX remote device
7113
Invalid parameter in a read operation found by the SY/MAX remote device
711D
Invalid route found by the SY/MAX remote device
7149
Invalid parameter in a write operation found by the SY/MAX remote device
714B
Invalid drop number found by the SY/MAX remote device
7101
Invalid opcode found by the SY/MAX server
7203
Invalid address found by the SY/MAX server
7209
Attempt to write to a write protected register found by the SY/MAX server
F720
Receiver overflow found by the SY/MAX server
7210
Invalid length found by the SY/MAX server
7211
Remote device not active, no connection (occurs when retry attempts and time-out have been used up), found by the SY/MAX server
7213
Invalid parameter in a read operation found by the SY/MAX server
721D
Invalid route found by the SY/MAX server
7249
Invalid parameter in a write operation found by the SY/MAX server
724B
Invalid drop number found by the SY/MAX server
7301
Invalid opcode in an MSTR block request from the Quantum translator
7303
Read/Write QSE module status (200 route address out of range)
7309
Attempt to write to a write protected register when a status write is carried out (200 route)
731D
Invalid route found by the Quantum translator.
Valid routes:
  • dest_drop, 0xFF
  • 200, dest_drop, 0xFF
  • 100+drop, dest_drop, 0xFF
  • All other routing values produce an error
734B
One of the following errors occurred:
  • No CTE (configuration extension table) has been configured
  • No CTE table entry has been made for the QSE model slot number
  • No valid drop has been specified
  • The QSE module has not been reset after the creation of the CTE.
    Note: After writing and configuring the CTE and downloading to the QSE module, the QSE module must be reset for the modifications to become effective.
  • When using an MSTR instruction no valid slot or drop has been specified