Module Type
|
8 Channel IN TC
|
External Power
|
Not required
|
Operating Voltage (Channel to Channel)
|
220 VAC @ 47 ... 63 Hz or 300 VDC max.
|
Bus Current required (Module)
|
280 mA
|
Power Dissipation
|
1.5 W
|
I/O map
|
10 input words
|
Error Detection
|
8 red LEDs to indicate out of range or broken wire conditons
|
TC Types:
J
K
E
T
S
R
B
|
Range (degrees C):
-210 ... +760
-270 ... +1370
-270 ... +1000
-270 ... +400
-50 ... +1665
-50 ... +1665
+130 ... +1820
|
Millivolt Ranges
(Open circuit detect can be disabled on these ranges)
|
-100 mV ... +100 mV
-25 mV ... +25 mV
|
TC Resistance / Max. Source Resistance
|
200 ohms for rated accuracy
|
Input Impedance
|
> 1 Mohms
|
Input Filter
|
Single low pass @ nominal 20 Hz plus notch filter at 50 / 60 Hz
|
Normal Noise Rejection
|
120 dB min. @ 50 or 60 Hz
|
Cold Junction Compensation (CJC)
|
Internal CJC operates 0 ... 60 degrees C (errors are included in the accuracy specification). The connector door must be closed.
Remote CJC can be implemented by connecting a TC (which monitors the external junction block temperature) to channel 1. Types J, K, and T are recommended for remote CJC.
|
TC Ranges
|
1 degree C (default)
0.1 degree C
1 degree F
0.1 degree F
|
Millivolt Ranges
|
100 mV range , 3.05 μV (16 bit)
25 mV range , 0.76 μV (16 bit)
|
![]() |
RISK OF TEMPORARY INVALID INITIAL INPUT TEMPERATURE VALUE.
Delay the temperature input processing by 2 seconds in the application:
Failure to follow these instructions can result in injury or equipment damage.
|
![]() |
RISK OF TEMPORARY INVALID INITIAL INPUT STATUS INFORMATION.
Delay the channel status information processing by 2 seconds in the application:
Failure to follow these instructions can result in injury or equipment damage.
|
TC Absolute Accuracy (see Note 1)
|
Types J, K, E, T (see Note 2):
+/- 2 degrees C plus +/- 0.1% reading
Types S, R, B (see Note 3):
+/- 4 degrees C plus +/- 0.1% reading
|
Millivolt Absolute Accuracy @ 25 degrees C
|
+/- 20 microV +/- 0.1% of reading
|
Accuracy Drift with Temperature
|
0.15 μV / degrees C + 0.0015% of reading / degrees C max.
|
Update Time
|
1 s (all channels)
|
Configuration Time
|
2 s (all channels)
|
Channel to Bus
|
1780 VAC @ 47 ... 63 Hz or
2500 VDC for 1 minute
|