Certification
|
Emergency Stop with double contact
|
Stop with single contact
|
---|---|---|
IEC 61508
|
SIL3
|
SIL1
|
IEC 62061
|
SIL3 CL
|
SIL1 CL
|
EN 954-1
|
Category 4
|
Category 2
|
EN ISO 13849-1
|
Category 4 PL “e“
|
Category 2 PL “c“
|
IEC 60204-1
|
Category stop 0
|
Category stop 0
|
Standard
|
Parameter
|
Emergency Stop with double contact
|
Stop with single contact
|
---|---|---|---|
IEC 61508 Ed2
|
PFD10y avg
|
1.04 x 10-4
|
3.14 x 10-3
|
PFD1y avg
|
1.03 x 10-5
|
3.15 x 10-4
|
|
PFHequ_1y
|
1.17 FIT
|
35.9 FIT
|
|
SFF channel 1
|
72.9 %
|
–
|
|
SFF channel 2
|
72.9 %
|
–
|
|
SFF global
|
98.4 %
|
72.9 %
|
|
Type
|
A
|
A
|
|
HFT
|
1
|
0
|
|
DC of proof test
|
99.9%
|
99.9%
|
|
SIL1
|
3
|
1
|
|
IEC 620612
|
SIL CL claimed
|
3
|
1
|
EN 954-13
|
Category
|
4
|
2
|
EN / ISO 13849-14
|
PL5
|
e
|
c
|
Category
|
4
|
2
|
|
PFD10y avg
|
1.04 x 10-4
|
3.14 x 10-3
|