Characteristics of the TSX PAY 262 module
(Original Document)
Introduction
This section describes the general characteristics of the TSX PAY 262 module, its input / output characteristics, operating conditions and applicable standards.
General characteristics
The following table shows the general characteristics of the TSX PAY 262 module
Safety functions
SS ESD and PS monitoring
Yes (1 to 12 single or double contacts)
Moving cover monitoring
Yes (de-synchronization > 400 ms)
Sensitive conveyor monitoring
No
I-manual control
No
Safety characteristics
External module power supply
A1-A2 terminal
Voltage
24 Vdc
Residual ripple
5%
Voltage limit
-20%...+25%
F1 fuse external supply protection (according to IEC 947-5-1)
<  1A (gL)
Maximum consumption
200 mA
Check threshold
< 19 Vdc
Maximum current call
0.5 A / 1 ms
safety circuit voltage
24 Vdc
Module protection
Internal electronic fuse > 250 mA and < 1 A
Insulation
Over-voltage category II (2 kV), pollution degree 2
Power dissipated in the module
< 5 W
Dimensions
H x W x D
150 x 36 x 120 mm
Weight
0.43 kg
Input characteristics
The following table shows the characteristics of the TSX PAY 262 module inputs
No. of safety channels
12 single or double SS ESDs
Reactivation / On button
Yes (S33-S34)
Single or double SS ESD selection
Yes with external shunt (B1)
Feedback loop
Yes (Y1-Y2)
Reactivation input monitoring
Yes with external shunt (Y3-Y4)
Call current
0,5 A / 1 ms
Input / Ground insulation
1000 Vrms actual 50/60 Hz - 1 min
Output characteristics
The following table shows the characteristics of the TSX PAY 262 module outputs:
Potential reference
None
Number and type of circuits
2
Circuits normally open with independent supplies
Rated voltage
24...240 Vac/24...125 Vdc
Outputs protected by fuses (compliant with EN VDE 0660 section 200 and IEC 60947-5-1
4 A (gL)
Rated thermal current
2 A (maximum 2.5 A)
ES request response time
< 12 ms
Mechanical durability
107 operations
Type of contact
Gold plated, AgSnO2 + 2 μm Au
Electrical durability
105 operations (with a normal load)
Output / Ground insulation
300 Vac insulation voltage compliant with VDE 0110, Section 1
Operating conditions
The following table shows the characteristics for using the TSX PAY 262 module:
Operating temperature
of the API
Temperature ranges:
  • 0°C...+60°C surrounding air temperature
  • 0°C...+40°C natural convection
  • Over +40°C with TSX FAN •• accessory
of the cabling accessory
-10...60°C
Humidity without condensation
5...95%
Storage temperature
-25...70°C
Insulation resistance
> 10 MΩ under 500 Vdc
Dielectric strength on Sub-D compliant with EN IEC 61131
500 Vrms, 50/60 Hz, 1 min
Operating altitude
0...2000 m (0...6562 ft)
Degree of protection compliant with IP IEC 60529
Terminals/Unit
IP20
Place of installation
IP54
Maximum capacity of screw terminal blocks
2 x 1 mm2 wires with termination,
Tightening torque
0.5 N•m
Standards
The following table shows the European and International standards the TSX PAY 262 module meets:
Specific for PLCs
EN 61131-2 (IEC 61131-2), CSA 22-2 No. 142, UL508
Electrical equipment on machines
EN 60204-1 (IEC 60204-1)
Emergency stop equipment
EN ISO 13850
Machine safety: Safety-related part of control systems
EN ISO 13849-1 and -2