The TSX PAY 262 modules provide the following functions:
-
Monitoring of emergency stop buttons and moving cover position switches for immediate halt (category 0 emergency stop in compliance with EN ISO 13850)
-
Channel de-synchronization detection (> 400 ms) in automatic start-up mode
-
Cabled safety block independent of Premium PLC operating mode
-
Guaranteed safety functions, whatever the safety system component failure, via:
-
Wiring of a (+) channel of an input x and of the (-) channel to another input (x+12) with a double contact
-
Self-checking and redundant design similar to the PREVENTA XPS-ASF range (cf. component catalog for Telemecanique safety applications)
-
Restart control via auxiliary input action: reactivation input
-
Possibility of monitoring the reactivation input by action on falling edge
-
Start-up mode selection using external cabling: manual, automatic or on falling edge
-
Automatic output check by monitoring their status reading in the feedback loop
-
Automatic input channel check by constant comparison of their respective statuses
-
Full safety system diagnostics via:
-
monitoring the SS ESD or PS input status readings
-
monitoring the reactivation input reading
-
monitoring the feedback loop reading
-
monitoring the safety output control reading
-
monitoring the safety system power supply status reading
-
monitoring the external module supply
-
Possibility to choose whether external supply is monitored or not