At a Glance
The general characteristics of the removable ABR-7••• electromechanical output relays for TELEFAST 2 bases are described in this section.
General Characteristics
This table shows the general characteristics of the ABR-7••• relays.
ABR-7••• reference |
S21 |
S23 |
S33 |
S37 |
||
---|---|---|---|---|---|---|
Relay width |
10 mm |
12.5 mm |
||||
Characteristics of the contacts |
||||||
Composition of the contacts |
1 F |
1 OF |
2 OF |
|||
Max. operating voltage according to IEC 947-5-1 |
Alternating |
250 V |
264 V |
|||
Direct |
125 V |
|||||
Thermal current |
4 A |
5 A |
||||
Frequency of current used |
50/60 Hz |
|||||
Alternating current load |
Resistive, load AC12 |
Voltage |
230 VAC |
|||
Current |
1.5 A |
1.2 A |
3 A |
2.5 A |
||
Inductive load AC15 |
Voltage |
230 VAC |
||||
Current |
0.9 A |
0.7 A |
1.7 A |
1.3 A |
||
Direct current load |
Resistive, load DC12 |
Voltage |
24 VDC |
|||
Current |
1.5 A |
1.2 A |
3 A |
2.5 A |
||
Inductive load DC13, L/R = 10 ms |
Voltage |
24 VDC |
||||
Current |
0.6 A |
0.45 A |
1.4 A |
1 A |
||
Minimum switching |
Current |
10 mA |
100 mA |
|||
Voltage |
5 V |
|||||
Response time |
State 0 to 1 |
10 ms |
13 ms |
15 ms |
||
State 1 to 0 |
5 ms |
13 ms |
20 ms |
|||
Maximum speed of function loading |
0.5 Hz |
|||||
Voltage assigned insulation |
Coil/contact |
300 V |
||||
Voltage assigned shock resistance (1.2/50) |
Coil/contact |
2.5 kV |
(1) | for 0.5 x 106 maneuvers |