Function
|
Description
|
Devices involved
|
---|---|---|
Basic
|
This function allows a simple control of the speed.
|
Altivar
|
MFB
|
This function allows control of the device through PLCOpen Motion function block library.
|
|
Standard
|
This function allows control of the speed and/or torque.
All the parameters that can be mapped are mapped in the supplemental PDOs for:
|
|
Advanced
|
This function allows control of the speed and/or torque.
Certain parameters can be configured and can also be mapped in the PDOs to allow:
|
|
Simple
|
Use this profile if the island does not contain high resolution analog I/O module or the TeSys U STB modules.
This profile contains:
This profile limits the number of index or subindex entries for any of the above objects to 32. If the island configuration exceeds this limitation, please use the Large profile.
|
STB NCO1010 & NCO2212
|
Extended
|
Use this profile if the island contains high resolution analog I/O module or the TeSys U STB modules.
This profile contains
This profile limits the number of index or subindex entries for any of the above objects to 32. If the island configuration exceeds this limitation, please use the Large profile.
|
|
Advanced
|
Use this profile if the island contains enhanced CANopen devices, special features as run-time parameters along with high resolution analog I/O module or HMI or the TeSys U STB modules.
This profile contains:
This profile limits the number of index or subindex entries for any of the above objects to 32. If the island configuration exceeds this limitation, please use the Large profile.
|
STB NCO2212
|
Large Profile
|
Use this profile if the island configuration does not fit any of the above profiles. This profile contains all the objects available for the STB island and hence will consume more memory address location in the CANopen master.
|
STB NCO1010 & NCO2212
|
Controlling
|
This function is especially created for CANopen communications with the built-in controller card and all the application cards (pump control,...).
|
Altivar 61/71
|
Basic
|
The basic level is designed to configure the valve terminal without CP extension.
|
Festo CPV
|
CP_Extension
|
This level is designed to configure I/Os including the CP extension.
|
|
Basic_DIO_only
|
The basic level is designed to configure the CPX with pneumatic valves and Digital I/O only.
|
Festo CPX
|
Generic_DIO_AIO
|
The generic DS401 level is designed to configure CPX valves and I/Os, including Analogue I/O modules.
|
|
Advanced
|
The advanced level is designed to configure the maximum I/Os and the complete parameters set.
|
|
Default
|
This feature is the default function for certain devices. It may not be modified.
|
All the slaves except ATV and Lexium
|