Physical characteristics of environment
(Original Document)
Table of characteristics
The following table describes the electrical characteristics of TSX SUP A02/A05 power supplies:
AS-i power supply module/block
TSX SUP A02/A05
Connection to screw terminals
max. capacity per terminal
mm2
A02:1 output terminal
A05: 2 terminals/output (24 V DC) and
1 terminal/output (30 V DC AS-i)
2 x 1.5 with cable end or 1 x 2.5
Temperature:
Storage
Operation
°C
°C
-
25 to +70
-10 to +60 (1)
Relative humidity
%
5-95
Cooling
%
By natural convection
User safety
SELV (EN 60950 and IEC1131-2)
Dielectric strength:
Primary/secondary
Primary/ground
Secondary/ground
V rms
V rms
V rms
3500
2200
500
Insulation resistance
Primary/secondary
Primary/ground
Mega Ohms
Mega Ohms
>=100
>=100
Leakage current
I<=3.5 mA (EN 60950)
Immunity to electrostatic
discharges
6 kV on contact/8 kV in air
(compliant with IEC 1000-4-2)
Electrical Fast Transient
2 kV (series mode and common mode commun on input and output)
Influence of electromagnetic
field
10 V/m (80 MHz at 1 GHz)
Rejected electromagnetic disturbances
(compliant with FCC 15-A and EN 55022 class A)
Test conditions: nominal U and I, resistive load,
cable: 1 meter horizontal, 0.8 meter vertical
Shock wave
Input: 4kV MC, 2kV MS Outputs: 2kV MF, 0.5 kV MS
(compliant with IEC 1000-4-5)
Vibration (2)
1 mm 3 Hz at 13.2 Hz 2g 57 Hz at 150 Hz
(compliant with IEC 68-2-6, FC test)
Degree of protection
IP 20.5
MTBF at 40°C
Lifetime at 50°C
H
100 000
H
30 000 (at nominal voltage and at 80% of nominal power)
(1) -10°C +55°C for TSX SUP A02/A05 power supply with product index II=01.
(2) compliant with IEC 68-2-6, FC test with module or block mounted on plate or panel.