Find the module reference in Control Expert:
Step
|
Action
|
1
|
Open the PLC Bus view.
|
2
|
Right-click on an empty slot and select New Device.
|
3
|
In the Part Number column, expand Communication to see the available modules, including the BMXNOR0200H.
|
NOTE: In a Modicon M340 system the total number of communication modules, such as BMX NOE 01•0 or BMXNOR0200H modules, cannot exceed two. The maximum Ethernet port for M340 system is 3 including the port on PLC. Therefore, a maximum of two BMXNOR0200H modules can be inserted in a M340 system.
The module is referenced as a BMX NOR 0200 in Control Expert. It is available under Communication in the New Device menu:
Only Ethernet port (channel 0) is configurable in Control Expert. Serial port is configured through the Web.
The Control Expert description for this module is “Ethernet TCP/IP, RTU module”: