Configuration with Control Expert
Original instructions
Introduction
Use these instructions to configure the IP address parameters for a BMENOR2200H module.
Access the Configuration
Access the IP address configuration in Control Expert:
Step
Action
1
Open a Control Expert project that includes a BMENOR2200H module.
2
Double-click the BMENOR2200H module to see the Configuration tab.
3
Configure these parameters:
  • IP Address: Enter the IP address of the module.
  • Subnet Mask: Enter a subnet mask that corresponds to the IP address.
  • Default Gateway: This is the IP address of the gateway to which messages for other networks are transmitted.
4
  • Click the Apply button to implement your configuration changes.
  • Click the OK button to implement your changes and close the dialog box.
Limitations
The BMENOR2200H module uses the FDR client basic service to get IP parameters from the CPU.
NOTE:
  • This module does not support DHCP or BOOTP.
  • This module does not locally store static IP parameters.
  • For details, refer to the description of the FDR client service configuration.