Explicit Exchange Objects of the IODDT of Types T_WEIGHING_ISPY101 and T_WEIGHING_ISPY101_2
(Original Document)
Introduction
This topic describes the explicit exchange objects of the IODDT of types T_WEIGHING_ISPY101 and T_WEIGHING_ISPY101_2, which apply to the TSX ISP Y101 module. It groups together word objects.
Example of declaration of a variable: IODDT_VAR1 of type T_WEIGHING_ISPY101.
Word Objects
The following table describes the meaning of the words. The requests used are those associated with the parameters (READ_PARAM, WRITE_PARAM, SAVE_PARAM, RESTORE_PARAM).
Standard Symbol
Type
Access
Meaning
Address
F1_FILTER
INT
R/W
F1 filter coefficient
%MWr.m.0.6
MANU_TARE
INT
R/W
Manual tare value
%MWr.m.0.7
HF_CUT
DINT
R/W
S0 high flow cut-off point (dosage)
%MDr.m.0.8
LF_CUT
DINT
R/W
S1 high flow cut-off point (dosage)
%MDr.m.0.10
Output Logic
The following table describes the meaning of the word bits OUTPUTS_LOGIC (%MWr.m.0.12). The requests used are those associated with the parameters (READ_PARAM, WRITE_PARAM, SAVE_PARAM, RESTORE_PARAM).
Standard Symbol
Type
Access
Meaning
Address
WEIGH_UNWEIGH
BOOL
R/W
Low Flow mask time
%MWr.m.0.12.0
Q0_OR_QOQ1
BOOL
R/W
Number of measurements used to calculate flow rate
%MWr.m.0.12.1
Word Objects
The following table describes the meaning of the words. The requests used are those associated with the parameters (READ_PARAM, WRITE_PARAM, SAVE_PARAM, RESTORE_PARAM).
Standard Symbol
Type
Access
Meaning
Address
MASK_TIME
INT
R/W
Low Flow mask time
%MWr.m.0.13
FLOW_MEAS_NB
INT
R/W
Number of measurements used to calculate flow rate
%MWr.m.0.14
F2_FILTER
INT
R/W
F2 filter coefficient
%MWr.m.0.15
F3_FILTER
INT
R/W
F3 filter coefficient
%MWr.m.0.16