Overview
Diagnostic is understood here as the time stamping modules functional diagnostic.
Modules diagnostic is performed on Control Expert or physically on the module.
BMX ERT 1604 T Module Diagnostic in Control Expert
BMX ERT 1604 T module diagnostic is performed differently depending on the module location in the system:
BMX ERT 1604 T placed in the local drop, diagnostic is done through:
the PLC language interface: %IWr.m.0.3 to %IWr.m.0.5. For details on implicit input parameters refer to chapter Language Objects for Channels.
or IODDT
T_ERT_TS_MOD
mapped on BMX ERT 1604 T channel 0 (%CHr.m.0). For details on BMX ERT 1604 T IODDTs refer to chapter IODDTs.
BMX ERT 1604 T placed in a Modicon X80 remote drop, diagnostic is done through the PLC device DDTs. For details on those device DDTs, refer to chapter Device DDT Names for Quantum EIO Remote I/O Adapter Modules.
BMX CRA 312 10 Module Diagnostic in Control Expert
A BMX CRA 312 10 module diagnostic is performed through the PLC device DDTs. For details on those device DDTs, refer to chapter Device DDT Names for Quantum EIO Remote I/O Adapter Modules.