Introduction
This topic lists the Quantum and Modicon X80 I/O devices that can be connected to an Ethernet remote I/O network.
To add I/O modules to an Ethernet remote I/O drop in Control Expert offline mode, click and drag the modules from the Hardware Catalog to the remote I/O drop in the bus editor. You can also double-click the rack slot in which you want to insert the I/O module and select from the New Device dialog box. The available I/O modules are listed in the following tables.
Quantum Analog and Digital Modules
These analog and digital I/O modules are supported in Quantum Ethernet remote I/O drops:
Input |
Output |
Input/Output |
---|---|---|
Analog I/O Modules: |
||
140 ACI 030 00 |
140 ACO 020 00 |
140 AMM 090 00 |
140 ACI 040 00 |
140 ACO 130 00 |
|
140 AII 330 00 |
140 AIO 330 00 |
|
140 AII 330 10 |
140 AVO 020 00 |
|
140 ARI 030 10 |
||
140 ATI 030 00 |
||
140 AVI 030 00 |
||
Digital I/O Modules: |
||
140 DDI 153 10 |
140 DDO 153 10 |
140 DDM 390 00 |
140 DDI 353 00 |
140 DDO 353 00 |
140 DDM 690 00 |
140 DDI 353 10 |
140 DDO 353 01 |
140 DAM 590 00 |
140 DDI 364 00 |
140 DDO 353 10 |
|
140 DDI 673 00 |
140 DDO 364 00 |
|
140 DDI 841 00 |
140 DDO 843 00 |
|
140 DDI 853 00 |
140 DDO 885 00 |
|
140 DAI 340 00 |
140 DAO 840 00 |
|
140 DAI 353 00 |
140 DAO 840 10 |
|
140 DAI 440 00 |
140 DAO 842 10 |
|
140 DAI 453 00 |
140 DAO 842 20 |
|
140 DAI 540 00 |
140 DAO 853 00 |
|
140 DAI 543 00 |
140 DRA 840 00 |
|
140 DAI 553 00 |
140 DRC 830 00 |
|
140 DAI 740 00 |
140 DVO 853 00 |
|
140 DAI 753 00 |
140 DIO 330 00 |
|
140 DII 330 00 |
||
140 DSI 353 00 |
Modicon X80 Analog and Digital Modules
These analog and digital I/O modules are supported in Modicon X80 Ethernet remote I/O drops:
Input |
Output |
Input/Output |
---|---|---|
Analog I/O Modules: |
||
BMX ART 0414 |
BMX AMO 0210 |
BMX AMM 0600 |
BMX ART 0814 |
BMX AMO 0410 |
|
BMX AMI 0410 |
BMX AMO 0802 |
|
BMX AMI 0800 |
||
BMX AMI 0810 |
||
Digital I/O Modules: |
||
BMX DDI 1602 |
BMX DDO 3202K |
BMX DDM 16022 |
BMX DDI 1603 |
BMX DDO 6402K |
BMX DDM 16025 |
BMX DDI 1604 |
BMX DDO 1602 |
BMX DDM 3202K |
BMX DAI 0805 |
BMX DDO 1612 |
|
BMX DAI 0814 |
BMX DAO 1605 |
|
BMX DAI 1602 |
BMX DAO 1615 |
|
BMX DAI 1603 |
BMX DRA 0804 |
|
BMX DAI 1604 |
BMX DRA 0805 |
|
BMX DAI 1614 |
BMX DRA 0815 |
|
BMX DAI 1615 |
BMX DRA 1605 |
|
BMX DDI 3202K |
BMX DRC 0805 |
|
BMX DDI 6402K |
Intelligent and Special Purpose Modules
These intelligent/special purpose modules are supported in Quantum and Modicon X80 Ethernet remote I/O drops:
Type |
Quantum Module |
Modicon X80 Module |
|
---|---|---|---|
BMX CRA 312 00 |
BMX CRA 312 10 |
||
expert |
140 ERT 854 10 |
— |
BMX ERT 1604T |
140 ERT 854 20 |
|||
140 ESI 062 10 |
|||
counting |
140 EHC 105 00 |
— |
BMX EHC 0200 |
140 EHC 202 00 |
— |
BMX EHC 0800 |
|
communication |
140 XBE 100 00 |
— |
BMX NOM 0200. Restrictions are described in chapter BMXNOM0200 Limitation and Implementation Rules. |
BMX EIA 100 (max of 1 per drop; may be combined with one BMX NOM 0200 module) |
|||
fiber cable conversion |
140 NRP 312 00/01 |
BMX NRP 0200/01 |
Modicon X80 Analog and Digital Module Versions
When the following modules are used in an EIO drop with a BMX CRA 312 10 adapter module, they require these versions (or later):
Module |
Product Version |
Hardware Release Level |
Software Version |
---|---|---|---|
BMX AMI 0410 |
PV5 |
RL5 |
SV1.1 |
BMX AMM 0600 |
PV5 (PV6) |
RL5 (RL6) |
SV1.2 |
BMX AMO 0210 |
PV7 (PV8) |
RL7 (RL8) |
SV1.1 |
BMX ART 0414 |
PV5 (PV6) |
RL5 (RL6) |
SV2.0 |
PV7 |
RL7 |
SV2.1 |
|
BMX ART 0814 |
PV3 (PV4) |
RL3 (RL4) |
SV2.0 |
PV5 (PV6) |
RL5 (RL6) |
SV2.1 |
|
BMX EHC 0200 |
PV3 |
RL3 |
SV1.1 |
BMX EHC 0800 |
PV3 |
RL3 |
SV1.1 |