Introduction

The LL984 Editor can display various information concerning variables attached to coils, contacts and function blocks.

This information is displayed above the respective coil, contact or function block node and can be displayed by tooltip, too.

4 Different Views

You can define 4 different views (View 1 to View 4 ) via Tools > Project Settings > Program > LL984 > Network Display.

According to the settings for View 1 to View 4 the LL984 Editor will show the following information:

  • address (e.g. %M100)

  • 984-address (e.g. 400100)

  • variable name

  • variable comment

  • descriptors 1 to 9

  • topological address

For detailed information on how to define the different views, please refer to Project Settings, section Program.

View Switching

You can switch between the different views defined, using CTRL+W or using the Change View Mode button ().

The button's tooltip shows the current view (View 1, 2, 3 or 4 .