At a Glance

These four tabs present the sections, SR program modules, event processing elements and macro steps to be imported.

Modifying the name of an element

To modify the name of an element, you must perform the following operations:

Step

Action

1

Double click the element to be modified.

2

Enter the new name for the element. You can only modify the name of a program module or of a macro step and the number of an event processing element.

3

Confirm your input by pressing Enter. Press Esc to cancel the input.

Elements that you can modify

The various elements that you can modify are as follows:

  • SR program sections and module

    • Target Address allows you to modify the name of an SR program section or module. This name comprises a maximum of 32 alphanumeric characters (‘A’...’Z’, ‘0’...’9’ and underscore character); the first character is a letter.

    • Comment allows you to modify the comment associated with the SR program section or module. This comment written on a single line may contain a maximum of 512 characters.

    • The new SR program section or module must be unique.

  • Event processing

    • Target Address allows you to modify the event processing number.

    • Comment allows you to modify the comment associated with the event processing element. This comment written on a single line may contain a maximum of 512 characters.

    • The new event processing must be unique.

  • Macro step

    • Target Address of the Macro allows you to modify the name of a macro step.

    • Comment allows you to modify the comment associated with the macro step. This comment written on a single line may contain a maximum of 512 characters.

    • The new macro step must be unique.