Questions and Answers
(Original Document)
List
Table of malfunctions
Malfunction
Possible causes
The cam processor does not switch to RUN mode
  • The module has not been recalibrated (bit %Ixy.0.0.i=0).
  • There is no encoder supply
  • Lack of auxiliary input supply
NOTE: If the faults have been masked, a fault can prevent the switch to RUN mode without appearing!
The cam processor changes to stop mode without modifying bit %Qxy.0.5 (PCAM_START_STOP)
Loading a recipe using the commands
  • WRITE_PARAM
  • RESTORE_PARAM
  • TRF_RECIPE
No action on the outputs
  • The outputs are already valid OUTS_ENABLE
  • Parallelization of a track without configured cam
  • Forced outputs
  • Inverted outputs
Loss of modifications to the current recipe
When switching to local mode, if the save has not been done when adjusting the recipe
Following modification to the configuration, the browser turns red and it is not possible to confirm the configuration
A parameter is no longer compatible with the new configuration
  • Switch to recipe adjustment
  • Click on No when requested to confirm
  • Modify the parameter
  • Confirm