Specification
|
Description
|
---|---|
5 V tolerance
|
+/- 5%
|
5 V current consumption
|
200 MA max.; @ < 100uF capacitive load
|
Specification
|
Description
|
---|---|
Temperature
|
0 - 60 degrees C. operating
-40 - +85 degrees C. storage
|
Humidity
|
5 - 95% RH (non-condensing)
|
Vibration
|
10 - 57 Hz @ 0.075 mmd.a
57 - 150 Hz @ 1g
|
Shock
|
+/- 15 G peak, 11ms, half sine-wave
|
Specification
|
Description
|
---|---|
Ethernet interface
|
Compliant with STP or UTP 100 ohm connection
|
Standard
|
Test Description
|
Application Port
|
TOP HAT
OPEN EQUIPMENT
Parameters/Limits
|
---|---|---|---|
EN 55011
|
Radiated interference
|
Enclosure
|
Class A
|
EN50140 /
IEC1000-4-3
|
Radiated
RF immunity
|
Enclosure
|
80-1000 Mhz
10 V/m
|
EN50140
|
Radiated
RF impulse immunity
|
Enclosure
|
900 Mhz
10 V/m
|
IEC 1000-4-2
(see note)
|
Electrostatic discharge
|
Enclosure
|
8kV Air
4 kV contact
|
ENV50141/
IEC 1000-4-6
(see note)
|
Conducted
RF immunity
|
Comm. port
|
.15-80 MHz
10 Vrms
|
IEC 1000-4-4
|
Fast transient burst
|
Comm. lines
|
1 kV cap. clamp
|
ENV 50142 /
IEC1000-4-5
|
Surges
|
Earth port(shield)
|
2 kV CM
|
IEC 1131-2 par 4.7.2
|
Protective earth continuity
|
Connector to Earth
|
30 A
<0.1 Ω
|