J892 ASCII Error Codes
(Original Document)
Introduction
Confidence tests can also be run on the J892 module to test the ASCII portion of the device. To establish the ASCII confidence test mode on the J892 board, set SW7 to 1 (to the left) on the eight-position DIP switch. This will run the loop test.
Error Codes
J892 ASCII board test error codes
Failed Diagnostic
READY
COMM ACTIVE
COM ERROR
INTERFACE ERROR
Machine Dead
OFF
OFF
OFF
OFF
PROM Test
Flashing
OFF
OFF
OFF
RAM Test
OFF
Flashing
OFF
OFF
HDLC Digital
Flashing
Flashing
OFF
OFF
HDLC Analog
OFF
OFF
Flashing
OFF
Serial Port Low
Flashing
OFF
Flashing
OFF
Interrupt Low
OFF
Flashing
Flashing
OFF
Serial Port High
Flashing
Flashing
Flashing
OFF
Interrupt High
OFF
OFF
OFF
Flashing
Baud Rate Low
Flashing
OFF
OFF
Flashing
Baud Rate High
OFF
Flashing
OFF
Flashing
Switch Test
Flashing
Flashing
OFF
Flashing
Modem Disconnect
OFF
OFF
Flashing
Flashing
Modem DSR Error
Flashing
OFF
Flashing
Flashing
With the exception of the switch test, these diagnostic error codes indicate an internal failure in the ASCII processing portion of the J892 interface.