Two toggle switches are located at the top of the module and are used to determine the type of communication with external devices. Both switches are user selectable.
1. Bin/BCD Switch
This toggle switch determines whether the output data is to be interpreted by the target devices as a BCD or a binary value.
2. Strobes Active Hi/Lo Switch
This toggle switch allows selection of either true-hi or true-lo for strobing output data.
NOTE: The relation between the I/O map selection, the BCD/binary switch setting, and the results at the output are summarized in the following table:
The following table identifies the relationship between the switch and I/O map facility.
I/O Map Selection
|
B864 Switch Setting
|
Result
|
Binary
|
BCD
|
BCD
|
Binary
|
Binary
|
Binary
|
BCD
|
BCD
|
Erroneous
|
BCD
|
Binary
|
BCD
|