B875–200 Configurable A/D Input, Specifications
(Original Document)
Specification Table
The following tables provides the specifications for the unit.
B875-200 Specifications
Analog Channels
B873-200 in I/O Map
Four
B875-200 in I/O Map
Eight
Voltage Range
Varies with selected input pack
Current Range
Thermocouple Types
RTD Types
Strain Gauge/Load Cell Types
Input Filter
Three pole or more low pass, with -3dB cut-off frequency of 4 Hz, 10% on low-band units, 10 kHz 10% on wide bandwidth units
Input Resistance
Current Mode
20 Ω
Voltage Mode
Refer to voltage mode table, below
Input Protection Normal Mode
All input packs can withstand 240 V RMS without damage, however, the fusible resistor used with the current input packs will be destroyed by overcurrent conditions
Note: Input over range or under range on an input pack will not produce reading errors on adjacent channels in excess of 1 count.
Common Mode
Each input pack can withstand 1500 V RMS
Rejection
In excess of 140 dB for all input packs except AS–5B40 and AS–5B41 which are 80 dB
Input Isolation
Input to OURBUS
1500 Vac RMS or 2500 Vdc for 1 minute
Input to Case
1500 Vac RMS or 2500 Vdc for 1 minute
Input to Input
1500 Vac RMS or 2500 Vdc for 1 minute
Conversion Resolution
12 bits all ranges
Out of Range Data
Four counts above and below range
Out of Range Error (flags)
Refer to out-of-range error table, below.
Out of Range Error (Flags)
Input Averaging
Options are 0, 2, or 4 samples
Throughput
1.7 ms typical for 4 channels, 4 ms for eight channels maximum
Power Required
+5 V
550 mA
+4.3 V
10 mA
-5 V
0 mA
Terminal Connector
AS–8535–000
Reference Type
Mapped as 8 registers input 3x
Input Type
BIN/BCD
The following table provides the resistance values for the voltage mode for the indicated input pack numbers.
Pack Number
In Range
Power Off and/or Over Range
AS–5B30
5 MΩ
40 kΩ
AS–5B31
650 kΩ
650 kΩ
AS–5B40
200 MΩ
40 kΩ
AS–5B41
650 kΩ
650 kΩ
The following table provides data on out-of-range errors (flags)
Data Flagged
Description
Not Ready
Bit 14 set high (4000 Hex)
Over Range
Bit 15 set high (800x Hex, x=1—4 bits over range)
Under Range
Bits 14 and 15 set high (c00xHex, x=1—4 bits under range)
Normal Data
Bits 14 and 15 are low, normal data range is 0—4095 (0—1FFF Hex)
The following table provides data on the accuracy of the input packs.
Input Pack
Calibration Accuracy at 25°C
*Accuracy Over Temp 0—60°C
Nonlinearity
Gain Drift***
Offset Drift***
AS–5B30
AS–5B40
Unipolar
0.15
0.73
0.05
.007%/°C
.008%/°C
Bipolar
0.20
0.78
0.05
.007%/°C
.008%/°C
AS–5B31
AS–5B41
Unipolar
0.15
0.62
0.05
.01%/°C
.002%/°C
Bipolar
0.20
0.67
0.05
.01%/°C
.002%/°C
AS–5B32
0.25
0.70
0.05
.01%/°C
.001%/°C
AS–5B47
0.1 1°C**
0.4 2°C
0.05
.007%/°C
1 V%/°C typ
AS–5B38
0.15
0.80
0.05
.010%/°C
1 V%/°C typ
AS–5B34
0.15
2.0
0.05
.01%/°C
.04%/°C
Unless noted all entries are% of full scale.
*Accuracy = Calibration + gain drift + offset + non linearity for the range 0—60°C ambient.
**Calibration accuracy for types J, K, T. For types R & S = 4°C. For type B = 6°C.
***Both gain and offset drift are from 25°C.