Introduction
Original instructions
The ConneXium NxS Switch
The internal switch control intelligence of a ConneXium NxS permits the redundant coupling of several network segments to a higher network segment.
The switch learns up to 2000 addresses, allowing the connection of several independent subnetworks. When reset, the switch deletes the learned addresses.
Ports’ link integrity is provided through link testing in accordance with IEEE 802.3. Additionally, if the receive cable pair signals are incorrectly connected (if RD+ and RD- are switched), the NxS automatically detects it and reverses the connection polarity. The ConneXium NxS switch uses shielded RJ-45 connectors that are internally wired in the accordance with the MDI-X specification.
Installation and Security Instructions
NOTICE
IMPROPER POWER SUPPLY
As electricity is used to operate this equipment, comply in every detail with the safety requirements specified in the operating instructions regarding the voltages to apply.
Failure to follow these instructions can result in equipment damage.
NOTICE
NON-SELV SUPPLY VOLTAGES
The ConneXium Switches 10/100 Mbps 5TX/2FL or 7TX units are designed for operation with safety extra-low voltage. Accordingly, connect only safety extra-low voltages (SELV) conforming to IEC950/EN60950/VDE0805 to the supply voltage connections.
Failure to follow these instructions can result in equipment damage.
Hardware
The following figure describes the interfaces, display elements, and controls of the ConneXium Switch 10/100 Mbps 5TX/2FX.
The following figure describes the interfaces, display elements, and controls of the ConneXium Switch 10/100 Mbps 7TX.