Operating mode
|
Standalone
|
Internal power dissipation (electric losses)
|
6.5 W
|
Network power consumption
|
Electric losses + (5.1 x Iout)1
|
Power factor
|
0.5
|
1: Iout: sum of currents consumption by all modules in rack (in A)
|
Input voltage
|
100 ... 276 VAC
|
Input frequency
|
47 ... 63 Hz
|
Input voltage total harmonic distortion
|
Less than 10% of the fundamental rms value
|
Input current
|
0.4 A @ 115 V AC
0.2 A @ 230 V AC
|
Inrush current
|
10 A @ 115 V AC
20 A @ 230 V AC
|
VA rating
|
50 VA
|
Fusing (external)
|
1.5 A slow-blow fuse
|
Input power interruption
|
1/2 cycle @ full load and minimum rated line voltage / frequency. No less than 1 s between interruptions.
|
Voltage
|
5.1 VDC
|
Current
|
3 A max.
|
0.3 A min.
|
|
Protection
|
Overcurrent, overvoltage
|