ABR-7••• reference
|
S21
|
S23
|
S33
|
S37
|
||
---|---|---|---|---|---|---|
Relay width
|
10 mm
|
12.5 mm
|
||||
Characteristics of the contacts
|
||||||
Composition of the contacts
|
1 F
|
1 OF
|
2 OF
|
|||
Max. operating voltage according to IEC 947-5-1
|
Alternating
|
250 V
|
264 V
|
|||
Direct
|
125 V
|
|||||
Thermal current
|
4 A
|
5 A
|
||||
Frequency of current used
|
50/60 Hz
|
|||||
Alternating current load
|
Resistive, load AC12
|
Voltage
|
230 VAC
|
|||
Current
|
1.5 A
|
1.2 A
|
3 A
|
2.5 A
|
||
Inductive load AC15
|
Voltage
|
230 VAC
|
||||
Current
|
0.9 A
|
0.7 A
|
1.7 A
|
1.3 A
|
||
Direct current load
|
Resistive, load DC12
|
Voltage
|
24 VDC
|
|||
Current
|
1.5 A
|
1.2 A
|
3 A
|
2.5 A
|
||
Inductive load DC13, L/R = 10 ms
|
Voltage
|
24 VDC
|
||||
Current
|
0.6 A
|
0.45 A
|
1.4 A
|
1 A
|
||
Minimum switching
|
Current
|
10 mA
|
100 mA
|
|||
Voltage
|
5 V
|
|||||
Response time
|
State 0 to 1
|
10 ms
|
13 ms
|
15 ms
|
||
State 1 to 0
|
5 ms
|
13 ms
|
20 ms
|
|||
Maximum speed of function loading
|
0.5 Hz
|
|||||
Voltage assigned insulation
|
Coil/contact
|
300 V
|
||||
Voltage assigned shock resistance (1.2/50)
|
Coil/contact
|
2.5 kV
|