Altitude Operating Conditions
The characteristics in the table below apply to the module BMX DRA 0804T for use at altitude up to 2000 m (6560 ft). When the module operates above 2000 m (6560 ft), apply additional derating.
For detailed information, refer to chapter Operating and Storage Conditions.
General Characteristics
This table presents the general characteristics for the BMX DRA 0804T module:
Module type |
Relay outputs for direct current |
||
Operating temperature |
-25...70 ºC (-13...158 ºF) |
||
Rated voltage |
Direct |
125 VDC |
|
Voltage range |
Direct |
100...150 VDC |
|
Maximum switching current |
0.3 A |
||
Response time |
Activation |
< 10 ms |
|
Deactivation |
< 10 ms |
||
Surge current maximum |
10 A capacitive |
t = 10 ms |
|
Built-in protection |
Against inductive over voltage in DC modes |
None. Fit a discharge diode on each output. |
|
against short-circuits and overloads |
None. Fit a fast-blow fuse of 0.5 A, 250 VDC for each relay. |
||
Reliability |
MTBF for continuous operation in hours at ambient temperature 30 °C (86 °F) |
2 683 411 |
|
Power dissipation |
3.17 W maximum |
||
Field to Bus (Dielectric strength) (at 50/60 Hz for 1 min.) |
2000 V actual |
||
Resistance of insulation (at 500 VDC) |
>10 MΩ |
||
Power supply consumption |
3.3 V |
Typical |
40 mA |
Maximum |
75 mA |
||
24 V (All channels stay at 1) |
Typical |
101 mA |
|
Maximum |
137 mA |
||
Point to point isolation |
1780 VAC rms |
||
Output current |
0.3 A at 125 VDC (resistive load) 100,000 ops. minimum |
||
0.1 A (L/R = 10 ms) 100,000 ops. minimum |
|||
Mechanical operations |
20,000,000 minimum |