Incomplete LD Generation
Original instructions
LD Generation Not Done Completely
In some cases, LD generation cannot be completed. This can happen when the algorithm allows an object that requires the same position as an existing object. In these cases, the pre-existing object is overwritten.
Messages are issued to make you aware of this:
{SAFETY_INTERLOCKS_PLC3 : [MAST]} :
(r: 8, c: 3) E1189 converter error: 'Overwrite happened when generating LD network - see report'
{SAFETY_INTERLOCKS_PLC3 : [MAST]} : (r: 8, c: 3) E1002 syntax error
Details in Conversion Report
In the conversion report, which may be opened after being imported through the hyperlink in the project tree, some additional detail about the message is given:
09:29:05.953 > Error: LD Object PTFDTP1_ENABLED with type coil overwritten
The user should compare the conversion result to a printout of the original section and correct the converted section accordingly.
Label or Link Views
If in LD networks, some links seem to have disappeared, it's because for a better reading they have been replaced by labels, to see the links, make a right click and select the Show as link option.