Overview
When you edit an M580 control project, certain configuration parameters are unavailable. You need to configure the corresponding attribute in the Topology Manager instead.
This topic lists the parameters of Control Expert Classic that are unavailable and that have a different name in the Topology Manager.
List of Parameters
Module/Service |
Parameter name and/or location in Control Expert Classic |
Attribute name and/or location in the Topology Manager of the |
---|---|---|
CPU |
ServicePort\Service Port and Service Port Mode |
Configuration\Physical Ports\ETH1 = Enabled and Service Port Mode |
CRA IP address configuration |
Configuration\Interfaces\Embedded Interface when you select the CRA adapter module |
|
BMECRA31310 |
CRA adapter module configuration\Parameters\ |
Configuration\Interfaces\Embedded Interface\CRA adapter module when you select the redundant |
BMENOC03•1 |
DTM\Channel Properties\Switch |
Configuration\Physical Ports |
DTM\Services\Service Port |
Configuration\Physical Ports\ETH1 |
|
DTM\Services\Network Time Service |
Services\NTP State |
|
BMENOC0321 |
DTM\Services\IP Forwarding |
Configuration\Physical Ports\BKP= Enabled and Interface = Enabled |
DTM\Services\IP Forwarding\Control Network |
Configuration\Interfaces\Embedded Interface\MainIP |
|
DTM\Services\IP Forwarding\Fieldbus Network |
Configuration\Interfaces\BKP_Interface\IP Address |
|
DTM\Services\IP Forwarding\Extended Network |
Configuration\Physical Ports\BKP= Enabled and \ETH1\Interface= Enabled and Interfaces\ETH1_Interface\IP Address |
|
BMENUA0100 |
IPConfig\Control Port\IPv4 |
Configuration\Interfaces\Embedded Interface\IPv4 A |
IPConfig\Backplane Port\IPv4 |
Configuration\Interfaces\BKP_Interface\IPA |
|
BMENUA0100 |
IPConfig\Fast Sampling Rate |
Services\OPC UA\Sampling Rate |
IPConfig\OPCUA TCP Listening Port |
Services\OPC UA\OPCUA TCP Listening Port |
|
Module or DTM\Security |
Enforce Security |
Security\Security Level = Enforced |
Unlock Security |
Security\Security Level = No |
|
Access Control = Enabled |
Security\Services\Access Control = Enabled and click |
|
Pre-Shared Key |
Security\Secure Protocol = IPsec |
|
DHCP |
Services\Address Server |
Services\DHCP Client\DHCP Server Name and |
Device Name (including Tens and Ones parameters) |
Services\DHCP Client\ |
|
Project Settings\General\Configuration\ |
Services\DHCP Server\ |
|
DTMs |
Advanced Configuration (to open the DTM. May vary by device.) |
Device context menu and select .For devices managing fieldbusses, edit the fieldbus first. |
DTM context menu\Device menu\Additional functions |
Device context menu, select , and button.For devices managing fieldbusses, edit the fieldbus first. |
|
I/O scanning |
DTM\Device List\Device X\Properties\Number |
Add device I/O profile to scanner in Communication Mapping view and select active I/O profile and Device Number |
DTM\Device List\Device X\Properties\Active Configuration |
Add device I/O profile to scanner in Communication Mapping view |
|
DTM\Device List\Device X\Properties\IO Structure Name\Structure Name |
I/O Profile\Profile Name X\Type Name |
|
DTM\Device List\Device X\Properties\IO Structure Name\Variable Name |
I/O Profile\Profile Name X\Instance Name |
|
Item mapping |
DTM\Device List\Device X\Properties\Items Management\Import Mode = Automatic/Manual |
I/O Profile\Profile Name X\Mapping = Automatic/Manual |
DTM\Device List\Device X\Properties\Items Management\Reimport Items |
I/O Profile\Profile Name X and change Mapping from Manual to Automatic |
|
Scanner\local slaves |
DTM\EtherNet/IP Local Slaves\Local Slave X\Active Configuration (adapter project) |
I/O Profile\Select DTM Reference and add local slave. When the local slave is deleted, Active Configuration is set to false in the control project. |
DTM\EtherNet/IP Local Slaves\Local Slave X\Items (scanner and adapter projects) |
I/O Profile\Select DTM Reference and add local slave and Local Slave X\Mapping = Manual and click (for adapter only) |
|
Syslog server |
Project Settings\General\PLC diagnostics\ |
Services\Syslog Server\ |